Optizen View

OPTIZEN View is a window-based PC software that can be used when you want to manage OPTIZEN Series spectrophotometer operation and data using a general PC.

It helps the user to check and control the measurement result of the sample through the PC, and to perform overall management of the instrument and measurement more comfortably in the Windows environment.

Main Charateristics

  • It can be saved and loaded in the form of a project to manage various types of modes (Photometric, Quantitation, Spectrum, Kinetics, etc.) at once.
  • Provide monitoring window to immediately check the currently set wavelength or measured value.
  • Provide graph and table functions to easily analyze complex spectral data. (Peak / valley, Crosshair, Tool tip, etc.)
  • Provides the function to analyze the rate of change in absorbance and the value of enzyme activity according to the enzyme reaction by measuring the change in absorbance over time.
  • Easy and simple report generation and output (print) function.
  • Provides various export functions. (Excel, PDF, Data Copy, HTML)
  • Multi-language support by country. (English, Chinese, Korean)
  • Control of the number of decimal places for absorbance, transmittance and concentration.
  • (Optional) Meets FDA 21 CFR Part 11 Compliance through OPTIZEN Secure linkage.
  • Essential Windows-based PC software for auditing and tracking user actions (login, measurement, storage, report, etc.) in OPTIZEN View.
  • Audit trail for users with login / logout function.
  • Provides check sum function to detect damage and deformation of measured data.
  • User management and user-specific group and authorization functions.

Product Features

  • User convenience
    It can be used intuitively by adopting a ribbon type design, and provides user convenience through quick slot function.
  • Easy and convenient data management
    Through the project management, various modes can be managed as one project, and only individual modes can be managed through the mode export and import functions.
  • Broad scalability
    You can control several types of OPTIZEN series spectrophotometers (POP, Alpha, etc.) with View software.
  • Prompt service
    Based on the unique technology of K Lab Co., Ltd., it is done domestically from design to manufacturing, so it can provide prompt service.
  • Continuous development
    New features can be provided through the installation of software updates (however, depending on the model, upgrade availability is required).
  • (Optional) Meets 21 CFR Part 11
    Provides functions to meet FDA 21 CFR Part 11 compliance, such as login, operation authority setting, and audit trail (however, separate purchase is required for Secure).

Product Information

  • Offering a help service with a graphic type.
  • Easily and quickly call up the information that is being measured or analyzed by registering it in you favorites.
  • Link it with PC by using OPTIZEN VIEW.
  • The measurement is possible in the optimal condition by checking the equipment’s operation time, lamp warm up condition and accumulated using time in real time.
  • The measurement monitoring is possible through choosing cell type without entering a mode and easily checking the current cell condition is possible through a change cell type icon according to the cell type condition or position.

Built-in four modes

  • Photometric Mode
    This mode is to measure the absorbance and concentration of the sample at a specific wavelength.
  • Quantitation Mode
    This is a mode for quantitative analysis of samples using a calibration curve.
  • Spectrum Mode
    · This mode allows the user to acquire an absorption or transmission spectrum in a desired wavelength band.
  • Kinetics Mode
    This mode is to measure the absorbance or transmittance of a sample over time.

Photometric Mode

  • This is a mode that can easily measure absorbance (Abs) or transmittance (% T) at a specific wavelength.
  • It is possible to set a factor (K) value, so it is possible to perform a simple quantitative test (C = K × A) of a known sample only by measuring absorbance (Abs).
  • Up to 8 wavelengths can be set, and absorbance by wavelength is measured automatically.
  • Up to 7 samples can be analyzed automatically using a multi-cell holder.

Quantitation Mode

  • This is a mode to measure and manage calibration curves and to measure the concentration of unknown samples.
  • Quantitative analysis of samples of interest can be performed using a calibration curve made up of samples of up to 8 concentrations. (Multi-cell holder can be used)
  • Provides four types of calibration curves: Linear (Zero-crossing), Linear, Quadratic, and Cubic.
  • Absorbance display function is also provided to separately display sample absorbance and reference absorbance.

Specifications

.
Item Minimum specification Recommended specification
Operating system Windows® 7, 8, 10 Windows® 8, 10
Processor Intel® Pentium® D or AMD™ Athlon™ 64 X2 Intel® Core 2 Duo E6600(2.4 GHz) or AMD™ Athlon™ 64 X2 5000+ (2.6 GHz) or more
Video NVIDIA® GeForce; 6800(256 MB) or ATI™ Radeon™ X1600 Pro(256 MB) or more NVIDIA® GeForce; 8800 GT(512 MB) or ATI™ Radeon™ HD 4850(512 MB) or more
Memory 2 GB RAM 4 GB RAM
Volume 1 GB or more free hard drive space 1 GB or more free hard drive space
Resolution Minimum 1920 x 1080 display resolution Minimum 1920 x 1080 display resolution